17
Control unit MGCplus
Operation modes
3.4
Control of the passages with "Control direction 1" and/or
"Control direction 2"
3.4.1
Explanations
You have the option to control the behaviour of the pedestrian gate using the
input functions "Control direction 1", "Control direction 2" and "Control open
mode".
In addition , the parameters "Control variant" and "Delay permanent open"
must be parameterised.
Page 41, "Control variant" And
Input functions "Control direction 1" and "Control direction 2"
With every state change "not set to set" you add a validation in the corre-
sponding direction. If the signal is longer than the time set for the "Delay per-
manent open" parameter, the free passage in the corresponding direction is
possible.
Parameter "Control variant"
Use this parameter to select the mode for the "Control direction 1", "Control
direction 2" and "Control open mode" inputs.
›
Variant 1: This variant is using the "Control direction 1", "Control direc-
tion 2" and "Control open mode" inputs. The open mode variants are se-
lected with the "Control open mode" input.
›
Variant 2: This variant is using only the "Control direction 1" and "Control di-
rection 2" inputs. If one of the inputs is permanently set, the corresponding
open mode variant is automatically selected.
Parameter "Delay permanent open"
You use this parameter to specify whether and after what time the permanent
open is activated for a permanent signal at the "Control direction 1" or "Con-
trol direction 2" input. Before the set time, a status change "not set to set" trig-
gers a validation. After the set time, the control unit switches to Permanent
open.