28
Control unit MGCplus
Digital inputs, digital outputs and relay outputs
Function
Description
Tailgating
An unauthorised access attempt of the "Tailgating", type was detected in
one direction.
Tailgating D1
Function such as "Tailgating" but only for direction 1.
Tailgating D2
Function such as "Tailgating" but only for direction 2.
Wing forced open
One wing was opened by force. This output is activated for 10 s.
Hit obstacle
A wing has hit an obstacle when opening or closing. This output is activated
for 10 s.
Warning light barri-
ers (PE beams)
This output is activated if one of the light barriers (PE beams) is occupied for
longer than the set time.
Page 52, "Warning light barriers (Parameter)".
GED1 red
Gate End Display connection
Connect the GED red in side 1 to this output.
GED1 green
Gate End Display connection
Connect the GED green in side 1 to this output.
GED2 red
Gate End Display connection
Connect the GED red in side 2 to this output.
GED2 green
Gate End Display connection
Connect the GED green in side 2 to this output.
Table 14:
Function digital outputs and relay outputs