Operational view > Main menu > Settings > Safety > Intrusion
Parameter
Description
Impact response
Close
Select the response for obstacle detection during the closing of the wings for
the unauthorised access attempt of the "Intrusion" type.
Factory setting
›
Lock
Table 23:
Intrusion
6.2.4.4
Wrong direction
Operational view > Main menu > Settings > Safety > Wrong direction
Parameter
Description
Do not close if free
Select the behaviour of the wings in case of an unauthorised access attempt
of the "Wrong direction" type for certain operating modes. Certain operating
modes are operating modes with "Free D1" or "Free D2".
Example "Contr. D1/Free D2"
If a validation is pending in direction 1 and a person enters the pedestrian
gate in direction 2, this is an unauthorised access attempt of the type
"Wrong direction". If you select the option "Activated [ X ]", the wings will
not be closed in this case, as one passageway in direction 2 is always free.
Options
›
Inactive [ ]:
›
Activated [ X ]
Factory setting
›
Inactive [ ]:
Do not close
Select the behaviour of the wings in case of an unauthorised access attempt
of the "Wrong direction" type. If you select the "Activated [ X ]" option, the
wings will not be closed in the event of an unauthorised access attempt of
the "Wrong direction" type.
Options
›
Inactive [ ]:
›
Activated [ X ]
Factory setting
›
Inactive [ ]:
Disable safety
Enable and disable the test of the safety light barriers (safety PE beams) for
an unauthorised access attempt of the "Wrong direction" type.
Factory setting
›
Inactive [ ]: