12
MGC control unit
Digital inputs, digital outputs and relay outputs
2.3
Digital power outputs of the MFM01 plug-in modules
The control unit is equipped with the plug-in module MFM01 with the function
"Magnets for locking".
Furthermore, the control unit can be equipped with additional plug-in modules
MFM01.
Power outputs 60 V / 3 A are available via the optional MFM01 plug-in
modules. The function is permanently assigned via the slot number.
Mag0083
8
2
1
3
4
5
Fig. 1:
Slot numbers
Slot number
Terminal plug-
in module
LED plug-in
module
Function
1
Magnets for locking
1
Red
Magnet RL1
2
Green
Magnet RL2
3
Yellow
–
2
On-site signalling, e.g. lights for zone controlled (ZC)
1
Green
Free in zone not controlled
direction
2
Red
Locked in zone not controlled
direction
3
Yellow
–
3
On-site signalling, e.g. lights for zone not controlled (ZNC)
1
Green
Free in zone controlled direction
2
Red
Locked in zone controlled direction
3
Yellow
–
4
–
5
–
Table 7:
Functions for MFM01 plug-in modules