30
MGC control unit
Description of menus and parameters
Operational view > Main menu > Setup > Random function
Parameter
Description
Hit range
The function depends on the selected mode.
For the "Counting" mode, use this parameter to set the value at which a hit
is to be generated.
For the "Random" mode, set the number range in which the random hits
must lie. For example, if you set the value to "100", the random hits must be
in the range 1 to 100.
IMPORTANT! The value for the "Count of hits" parameter can be a maximum
of 40% of the value for the "Hit range" parameter. If the value set for the
"Count of hits" parameter is too high, the "Count of hits" parameter is
automatically adjusted.
Setting range
›
10 to 10000
Factory setting
›
1000
Count of hits
Set the number of hits to be generated in the set Count of hits.
IMPORTANT! The value for the "Count of hits" parameter can be a maximum
of 40% of the value for the "Hit range" parameter. If the value set for the "Hit
range" parameter is too high, the "Hit range" parameter is automatically
adjusted.
Setting range
›
1 to 1000
Factory setting
›
10
Delete validation
Use the "Delete validation" parameter to specify whether the validation is to
be deleted automatically in the event of a random hit. Validations are only
deleted if the option "Entry" or "Exit" has been selected for the parameter
"Direction".
Options
›
Activated [ X ]
Select this option if you want the check to take place before the passage.
The user leaves the area via a separate passage.
›
Inactive [ ]
Select this option if you want the passage to take place when the hit is
confirmed. In this case, the check is carried out after the passage.
Factory setting
›
Inactive [ ]