MGC control unit
Description of menus and parameters
4.4
Menu "Service"
4.4.1
Gate HW
IMPORTANT!
By default, the pedestrian gate is delivered with the
configuration "Locking normally open". If you want a different
configuration, convert the locking and adjust the parameters
"Invert magnet RL1" and "Invert magnet RL2". Possible
configurations:
ä
For the conversion of the locking, see separate operating
instructions "Full height turnstile MPT-333 (Doc.ID: 5817,0028)".
Operational view > Main menu > Service > Gate HW
Parameter
Description
Invert Magnet RL1
This parameter is used to specify the switching signal for the Magnet RL1 for
locking.
Options
›
Inactive [ ]: Normally closed. In the event of power failure, the lock is
locked and the centre pillar can be turned.
›
Activated [ X ]: Normally open. In the event of power failure, the lock is
unlocked and the centre pillar can be turned.
Factory setting
›
Activated [ X ]
Invert Magnet RL2
This parameter is used to specify the switching signal for the Magnet RL2 for
locking.
Options
›
Inactive [ ]: Normally closed. In the event of power failure, the lock is
locked and the centre pillar can be turned.
›
Activated [ X ]: Normally open. In the event of power failure, the lock is
unlocked and the centre pillar can be turned.
Factory setting
›
Activated [ X ]