33
MGC control unit
Description of menus and parameters
Operational view > Main menu > Service > Gate HW
Parameter
Description
Exit direction
Unless otherwise ordered, the turnstile is delivered for the "Entrance side
right" design. The control unit is parameterised accordingly. If the version
"entrance side right" does not fit, the parameterisation can be changed via
the parameter "exit direction" for the version "entrance side left".
ä
Note that if you change the parameter, you must also convert the support
beam.
Options
›
Right: All relevant parameters are parameterised for the version "Entrance
side right". On passage in zone controlled direction, the centre pillar can
be turned counter-clockwise.
›
Left: All relevant parameters are parameterised for the version "Entrance
side left". On passage in zone controlled direction, the centre pillar can be
rotated clockwise.
Factory setting
›
Depending on the version ordered
Table 17:
Gate HW
Ma
g0088
7
1
2
Fig. 19: Locking unit configuration "Normally open"
1 Magnet RL1
2 Magnet RL2