8
MGC control unit
Digital inputs, digital outputs and relay outputs
2
Digital inputs, digital outputs and relay outputs
WARNING
Improper wiring and parameterisation of the control unit!
Improper wiring and parameterisation of the control unit can
lead to undesired functions and thus to injuries.
›
Only qualified electricians or technician with additional
"electrical safety expert" training may wire and parameterise
the control unit.
›
The electrical connection of the signal transmitters to the IN1
to IN8 inputs must fit the parameterisation.
ä
For parameterisation see Page 13, chapter 3.
2.1
Digital inputs
ä
For the definition "Entry" and "Exit" see Page 40, chapter 5.1.
By parameterising the inputs, you assign certain functions to the inputs. For
example, if you parameterise the "Over-climb detection" function for input
IN7, you must connect a sensor for the over-climb detection to this input.
If the function is marked with "|", the input is inverted (Fail Safe).
The following functions are assigned to the inputs as default settings.
Clamp
Description
Function
IN1
Digital Input 1
| Emergency open
IN2
Digital Input 2
Open entry
IN3
Digital Input 3
Open exit
IN4
Digital Input 4
Random function
IN5
Digital Input 5
Confirm warnings
IN6
Digital Input 6
Inhibit opening
IN7
Digital Input 7
Sensor B1
IN8
Digital Input 8
Sensor B2
Table 3:
Factory settings "Digital inputs"