26
MGC control unit
Description of menus and parameters
4.2
Menu "Setup"
4.2.1
Hold-open time
Operational view > Main menu > Setup > Hold-open time
Parameter
Description
Hold-open time
Set the hold-open time.
The hold-open time is started by an opening pulse by a control device, such
as a card reader. A passage should take place within the set hold-open time.
If there is no passage during the hold-open time, the direction is blocked.
With the setting 0 s, the direction remains open until a passage takes place.
Setting range
›
0 to 60 s
Factory setting
›
7 s
Table 11:
Hold-open time
4.2.2
Permanent open
Operational view > Main menu > Setup > Permanent open
Parameter
Description
Permanent open
You use this parameter to specify whether and after what time the
permanent open is activated for a permanent signal at the "Open entry" or
"Open exit" input.
Example option "after 3 s"
If the signal is present at the "Open entry" or "Open exit" input for 3
seconds, the system switches to the "Permanent open" operating mode. As
soon as the signal is no longer present at the input, the direction is
immediately blocked.
Case Hold-open time < time "permanent open"
If a shorter time has been set for the parameter "hold-open time" than for
the parameter "permanent open", the system switches to the operating
mode "permanent open" immediately after the hold-open time has elapsed.
Options
›
Inactive
›
After 3 s
›
After 10 s
Factory setting
›
After 3 s
Table 12:
Permanent open