27
MGC control unit
Description of menus and parameters
4.2.3
Interlock
Operational view > Main menu > Setup > nterlock
Parameter
Description
Interlock
Activate and deactivate the "Interlock" function.
If the interlock has been activated, further rotation of the centre pillar is
blocked for 1 second after each pass. This ensures that the centre pillar
remains safely in the end position. If many people pass the pedestrian gate
(high throughput), the option "Inactive [ ]" may be useful.
Operating mode "with vend count"
›
Inactive: The centre pillar is not locked between the passages until all
passages have been completed.
›
Activated: After each passage, the centre pillar is locked for 1 second.
Options
›
Inactive [ ]
›
Activated [ X ]
Factory setting
›
Inactive [ ]
Table 13:
Interlock
4.2.4
Vend count
Operational view > Main menu > Setup > Vend count
Parameter
Description
Entry
Shows the current counter for validations for the passages in zone controlled
direction.
Exit
Displays the current counter for validations of passages in the zone not
controlled direction.
Max. pulse count
Set the value for the maximum number of pulses. The pulses are counted up
to the set value.
Setting range
›
0 to 10
Factory setting
›
3
Max. pulse w/o
passage
(Max. pulse without
passage)
Set the value for the maximum number of pulses without passages.
This value is used to check the connected validation device, e.g. card reader.
If the counter value is above the set value, a warning message is issued.
Setting range
›
5 to 10
Factory setting
›
5
Table 14:
Vend count