28
MGC control unit
Description of menus and parameters
4.2.5
Signalling
Operational view > Main menu > Setup > Signalling
Parameter
Description
Buzzer/Siren
Activate events for which an acoustic signal is to be triggered. Connect the
acoustic signal to the "Buzzer/Siren (alarm)" output.
An acoustic signal is possible for the following events:
›
Validation pulse
›
Error
›
Random hit
›
Passage
Options
›
Inactive [ ]
›
Activated [ X ]
Factory setting
›
Inactive [ ]
GED mode entry
Set the behaviour of the optional GEDs.
Options
›
Off: The display is dark.
›
Red: The display is permanently red.
›
Green: The display is permanently green.
›
Standby red: The display is red when locked. When released, the display
turns green. The display is red during a passage in the opposite direction.
›
Standby off: The display is off when locked. When released, the display
turns green. The display is red during a passage in the opposite direction.
›
Standby green: The display is green when locked. When released, the
display flashes green. The flashing frequency is increased at the end of the
hold-open time. The display is red during a passage in the opposite
direction.
Factory setting
›
Standby red
GED mode exit
ä
"GED mode entry" parameter.
Table 15:
Signalling