Control unit MGC mTripod
Digital inputs, digital outputs and relay outputs
Output function
Description
–
Outputs that you assign this function "–" to are deactivated.
| Error
When the control unit recognises any safety-relevant error or error, the
output with this function is deactivated (closed-circuit principle).
| Warning
When the control unit recognises any "Warning", the output with this
function is deactivated (closed-circuit principle).
Gate ready
Pedestrian gate is ready for operation
This output is activated as soon and as long as the pedestrian gate is ready
for operation.
Passage pulse left
Counter pulse for a passage from left
When the blocking element reaches an end position in the passage direction
from left, a counter pulse of 300 ms is output from this output. A counter
pulse is also emitted in the "Permanent open" operating mode.
Passage pulse right
Counter pulse for a passage from right
When the blocking element reaches an end position in the passage direction
from right, a counter pulse of 300 ms is output from this output. A counter
pulse is also emitted in the "Permanent open" operating mode.
Passage clear left
Display for the free passage from left
When the passage from left is cleared, a permanent signal is output from
this output.
You can also use this output to lock a pulse encoder, e.g. a card reader, for
passage from right if passage from left is cleared.
Passage clear right
Display for the free passage from right
When the passage from right is cleared, a permanent signal is output from
this output.
You can also use this output to lock a pulse encoder, e.g. a card reader, for
passage from left if passage from right is cleared.
Home position
Blocking element in Home position (Home Position)
When the blocking element is in one of the end positions, a permanent
signal is output.
Rotating from left
As long as the blocking element is turned from the left, a permanent signal
is emitted via this output.
Rotating from right
As long as the blocking element is turned from the right, a permanent signal
is emitted via this output.
Climbing/
Crawling
Climbing or crawling attempt detected
This output is activated as soon as a climbing or a crawling attempt is
detected. If an individual release or Permanent open is present, the output
is not activated.
After one passage, the sensors may continue to be occupied for approx. 1.5
seconds without triggering an alarm.