Control unit MGC mTripod
Digital inputs, digital outputs and relay outputs
Output function
Description
Vandalism
The output is activated in the following cases:
›
A user tries to pass through the pedestrian gate without authorisation
(validation).
›
A user is authorised for passage, but moves the blocking element against
the released direction.
›
A user has first moved the blocking element correctly in the released
direction, but then moves it back in the other direction with more than
the motor force.
The output remains activated until the blocking element is in an end
position.
Buzzer/Siren (alarm) Acoustic signal transmitter connection
An acoustic signal transmitter is connected to this output.
You can parameterise the events for which an acoustic signal is to be
triggered via the "Buzzer/Siren" parameter in the "Signalling" menu.
Random hit
Hits of the random check function, signal transmitter
The random check function generated a hit. You can connect a signal lamp
or a siren to this output, for example.
The passage remains blocked until the random hit / validation is confirmed
with a 0 V pulse at the "Random check function" input.
Service mode active Pedestrian gate in service mode
As soon as the service mode is activated via the service switch on the MGC
control unit, this output is activated.
GED red left
Gate End Display connection
Connect the GED red left to this output.
GED green left
Gate End Display connection
Connect the GED green left to this output.
GED red right
Gate End Display connection
Connect the GED red right to this output.
GED green right
Gate End Display connection
Connect the GED green right to this output.
Table 6:
Function digital outputs and relay outputs