46
Control unit MGC mTripod
Description of menus and parameters
6.2
"Settings" menu
6.2.1
Hold-open time
Operational view > Main menu > Settings > Hold-open time
Parameter
Description
Hold-open time
Set the hold-open time.
The hold-open time is started by a validation by a control device, such as a
card reader. A passage should take place within the set hold-open time. If
there is no passage during the hold-open time, the direction is blocked.
With the setting 0 seconds, the direction remains open until a passage takes
place.
Setting range
›
0 to 60 s
Factory setting
›
7 s
Table 20:
Hold-open time
6.2.2
Permanent open
Operational view > Main menu > Settings > Permanent open
Parameter
Description
Permanent open
You use this parameter to specify whether and after what time the
permanent open is activated for a permanent signal at the "Open from left"
or "Open from right" inputs.
Example "After 3 s" option
If the signal is present at the "Open from left" or "Open from right" input for
3 seconds, the system switches to the "Permanent open" operating mode.
As soon as the signal is no longer present at the input, the direction is
immediately blocked.
Options
›
Deactivated
›
After 3 s
›
After 10 s
Factory setting
›
After 3 s
Table 21:
Permanent open