13
Control unit MGC mTripod
Digital inputs, digital outputs and relay outputs
2.2
Digital outputs and relay outputs
Definition of "Left" and "Right":
By parameterising the outputs, you assign certain functions to the outputs. For
example, if you parameterise the "Buzzer/Siren (alarm)" function for output
NO2, you must connect an acoustic signal transmitter to this output.
If the function is marked with "|", the output is inverted (closed-circuit
principle).
The following functions are assigned to the outputs as default settings:
Clamp
Description
Output function
DO1
Digital output 1
GED red left
DO2
Digital output 2
GED green left
DO3
Digital output 3
GED red right
DO4
Digital output 4
GED green right
NO1
Relay output 1
Random hit
NO2
Relay output 2
Buzzer/Siren (alarm)
NO3
Relay output 3
Climbing/Crawling
NO4/NC4
Relay output 4
Passage clear Left
NO5/NC5
Relay output 5
Passage clear Right
NO6/NC6
Relay output 6
Home position
Table 5:
Factory setting digital outputs and relay outputs
NOTICE
Changing the assignment of the terminals DO1, DO2, DO3, DO4
and NO2 and the factory default functions!
By default, the terminals are wired for the listed factory setting.
A change will cause the pedestrian gate to malfunction.
›
Do not change the assignment of the listed terminals.
NOTICE
Malfunction due to excessive output current at terminal X2!
The maximum output current at terminal X2 is limited to 300 mA
by a self-resetting fuse.
›
Make sure that the maximum output current is not exceeded.
›
If necessary, supply components such as other illumination
with an additional power supply unit. The additional power
supply unit must be installed outside the pedestrian gate.