16
Control unit MGC mTripod
Digital inputs, digital outputs and relay outputs
2.3
Digital power outputs of the MFM01 plug-in modules
You can equip the control unit with up to 4 optional MFM01 plug-in modules.
Power outputs 60 V / 3 A are available via the optional MFM01 plug-in
modules. The function is permanently assigned via the slot number.
Mag0083
8
2
1
3
4
5
Fig. 1:
Slot numbers
Slot number
Terminal plug-
in module
LED plug-in
module
Function
1
Locking unit / drop arm
1
Red
Locking magnet left
2
Green
Locking magnet right
3
Yellow
Drop arm
2
Passage right (frame illumination) / floor illumination
1
Red
Passage blocked right
2
Green
Passage clear Right
3
Yellow
Floor illumination
3
Passage left (frame illumination)
1
Red
Passage blocked left
2
Green
Passage clear Left
3
Yellow
Not usable
4
Drop arm / vandalism
1
Red
Drop arm
2
Green
Not usable
3
Yellow
Vandalism
5
Not usable
Table 7:
Functions for MFM01 plug-in modules
Summary of Contents for mTripod
Page 86: ...86 Control unit MGC mTripod...
Page 90: ...90 Control unit MGC mTripod...