                           Model JM4

Magnetostrictive Level  Transmitter

HART Installation and Operating Manual

Software v1.x

Summary of Contents for Jupiter JM4

Page 1: ...Model JM4 Magnetostrictive Level Transmitter HART Installation and Operating Manual Software v1 x...

Page 2: ...ation labor claims direct or consequential damage or expense arising from the installation or use of equipment There are no other warranties expressed or implied except special written warranties cove...

Page 3: ...nents or connector pins Make sure that all electrical connections are completely made and none are partial or floating Ground all equipment to a reli able earth ground 1 1 4 Site Preparation Power Sup...

Page 4: ...eft to right in Figure 1 4 top mount top mount offset bottom mount offset All of these configurations are available with one or two magnetic floats two floats are necessary to measure total AND interf...

Page 5: ...th an insulation blanket secure the blanket over the chamber then be sure to place the transmitter in the smaller of the two grooves leaving the larger groove for visual indication Figure 1 6b 1 2 7 V...

Page 6: ...e to the terminal 6 Replace and tighten the cover to the transmitter wiring compartment before applying power 1 4 2 Intrinsically Safe An Intrinsically Safe IS installation potentially has flammable m...

Page 7: ...avigation and data entry The Model JM4 user interface is hierarchical in nature best de scribed as a tree structure Each level in the tree contains one or more items Items are either menu labels or pa...

Page 8: ...The user password can be changed to any numerical value up to 59999 When the transmitter is programmed for password protection a password is required whenever configuration values are changed User Pa...

Page 9: ...AIN MENU will result in an LCD presentation as shown at left The small down arrow shown at the right hand side of the screen is the indication that more items are available below and can be accessed b...

Page 10: ...rs Upper Thickness Units Inches Feet Millimeters Centimeters Meters Device Setup Main Menu Home Screen Product Name read only Orion S N read only DIGITAL BOARD read only ANALOG BOARD read only Physica...

Page 11: ...l Display Config Advanced Config Factory Config Blocking Distance 0 to 50 feet 0 m to 15 m Minimum Separation 0 to 28 inches 0 cm to 71 cm Zero Offset 50 to 50 feet 15 m to 15 m Level Trim 2 to 2 feet...

Page 12: ...JM4 software Device Descriptions Refer to your HART Communicator Manual for update instructions 1 6 1 Connections A HART communicator can be operated from a remote loca tion by connecting it to a rem...

Page 13: ...6 4 HART Menu Model JM4 NOTE Numbered menu boxes below correspond to numbered tables on Section 1 6 5 1 PV 2 PV Analog Output 3 PV Output 4 Device Setup 5 Setup Wizard 6 Diagnostics 7 Measured Values...

Page 14: ...his value corresponds to the level of the upper surface 2 PV Analog Output Digital representation that tracks the Analog Output Number 1 under normal operating modes Analog Output Value Value that tra...

Page 15: ...ion or calibration has been changed by a host application or from a local operator interface 9 Device ID Uniquely identifies the Field Device when combined with the Manufacturer Identification and Dev...

Page 16: ...n operational endpoint from which the alarms associated with the Analog Value and the alarms associated with the Digital Value representation are derived Ifc 4mA Set Point Thk 4mA Set Point Vol 4mA Se...

Page 17: ...t to match the polarity of the first portion of the sine wave signal of a direct insertion float or the first portion of the M shaped signal of an external mount probe Ifc Lvl Polarity 1 6 5 HART Menu...

Page 18: ...es only 1 6 5 HART Menu Items cont 19 Display Description 1 Present Temperature Present temperature measured in the electronics compartment 2 Max Temperature Maximum temperature measured in the electr...

Page 19: ...e mode this value corresponds to the strength of the upper level signal 6 Ifc Echo Strength Relative strength of the interface level signal 7 Analog Output Allows for configuration of the 4 20mA Analo...

Page 20: ...valuable proactive method of troubleshooting The device not only tells the user what wrong but also and more impor tantly offers suggestions on how to solve the problem All of this information can be...

Page 21: ...Specification and Maintenance Required The FOUNDATION fieldbus transmitter version of the Model JM4 was implemented according to the Field Diagnostics Pro file which is consistent with the objectives...

Page 22: ...upper level threshold Check echo curve for noise levels Echo Rejection may be required Consult Factory Swipe probe with pocket magnet to eliminate possibility of residual magnetism High Noise Ifc Thre...

Page 23: ...rtical Flat factory default Vessel Type Vertical Elliptical Vertical Spherical Vertical Conical Custom Table Rectangular Horizontal Flat Horizontal Elliptical Horizontal Spherical or Spherical Note Ve...

Page 24: ...roubleshooting this parameter gives the user the ability to reset the Model JM4 transmitter configuration Unique to the Model JM4 transmitter is the ability for Orion In struments to fully pre configu...

Page 25: ...EC60079 11 2011 IEC60079 15 2010 IEC60079 31 2008 SPECIAL CONDITIONS OF USE 1 The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or friction Care must...

Page 26: ...NSTALLATION REFERENCE ALL APPLICABLE NOTES FROM PAGE 2 99 5074 001 Ui Vmax 24V Ii Imax 280mA Pi 1 93W or Any approved termination on with R 90 100 C 0 2 2 F Any FM CSA Approved Intrinsically Safe Asso...

Page 27: ...upon request Environment Ambient Temperature Range Transmitter 40 F to 176 F 40 C to 80 C LCD 5 F to 176 F 20 C to 80 C Process Temperature External Mount 320 F to 850 F 195 C to 454 C Direct Inserti...

Page 28: ...tion 75 NPT High Temp Cryo Direct Insertion 1 BSP 16 92 429 7 Direct Insertion 2 BSP 17 17 436 Direct Insertion 2 NPT 2 5 4 Physical Specifications Transmitter inches mm 18 92 480 5 22 92 582 1 Direct...

Page 29: ...SIC MODEL NUMBER JM4 Jupiter 4th Generation Magnetostrictive Level Transmitter 4 POWER 5 24 VDC Two Wire 5 SIGNAL OUTPUT 1 4 20 mA with HART 2 Foundation Fieldbus Communications 6 SAFETY OPTIONS 1 SIL...

Page 30: ...ct Insertion float provided or unit is External Mount Jupiter 99 Custom Direct Insertion float not listed in standard offering below One Float Total Level Only Digit 10 1 AA 316L SS MIN SG 0 83 2 00 O...

Page 31: ...r External Mount Probe 0 0 0 2 1 3 2 4 5 6 7 8 9 10 11 12 13 14 15 8 INSTALLATION CONSIDERATIONS 0 No mounting clamps required Chamber Clamp Sizes for MLI Mount Without High Temperature Insulation 1 2...

Page 32: ...closure Fault A defect or failure in a circuit The current mA value unit defaults to 3 6 22 or Hold when a diagnostic condition occurs Feedthrough A small connecting cavity between the main housing co...

Page 33: ...to user s meter DCS input etc Two Wire An electrical instrument design that uses one set of wires to provide both the supply power and process measurement signal The process measurement is achieved b...

Page 34: ...probe 4mA or 0 20mA or 100 Is moderate to heavy vibration present Is turbulence or flow present Additional application details that could impact performance Will existing chamber or stilling well be u...

Page 35: ...red trademarks of Magnetrol International Incorporated HART is a registered trademark of the HART Communication Foundation PACTware is trademark of PACTware Consortium CSA logotype is a registered tra...