background image

A N T E N N A   M O D E L   N U M B E R

14

3

|

CONFIGURATION/STyLE

1

1

1

2

" Horn

2

2" Horn

3

3" Horn

4

4" Horn

4–5

|

PROCESS CONNECTION - SIZE/TyPE

R

B

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

ASME Flanges

EN (DIN) Flanges

1–2 

TEChNOLOGy

R B

PULSAR Radar Antennas - 26 GHz

31

1

1

2

" NPT thread

41

2" NPT Thread

32

1

1

2

" BSP (G 1

1

2

") thread

42

2" BSP (G2") Thread

43

2" 150# ASME raised face flange

DA

DN 50, PN 16

EN 1092-1 Type A

44

2" 300# ASME raised face flange

DB

DN 50, PN 25/40

EN 1092-1 Type A

45

2" 600# ASME raised face flange

DD

DN 50, PN 63

EN 1092-1 Type B2

53

3" 150# ASME raised face flange

EA

DN 80, PN 16

EN 1092-1 Type A

54

3" 300# ASME raised face flange

EB

DN 80, PN 25/40 

EN 1092-1 Type A

55

3" 600# ASME raised face flange

ED

DN 80, PN 63

EN 1092-1 Type B2

63

4" 150# ASME raised face flange

FA

DN 100, PN 16

EN 1092-1 Type A

64

4" 300# ASME rased face flange

FB

DN 100, PN 25/40 EN 1092-1 Type A

65

4" 600# ASME raised face flange

FD

DN 100, PN 63

EN 1092-1 Type B2

73

6" 150# ASME raised face flange

GA

DN 150, PN 16

EN 1092-1 Type A

74

6" 300# ASME raised face flange

GB

DN 150, PN 25/40 EN 1092-1 Type A

75

6" 600# ASME raised face flange

GD

DN 150, PN 63

EN 1092-1 Type B2

CONSTRUCTION CODES

0

Industrial

K

ASME B31.1

L

ASME B31.3

M

ASME B31.3 & NACE MR0175 / MR0103

N

NACE MR0175 / MR0103

FLANGE OPTIONS

0

None

Summary of Contents for Pulsar R86

Page 1: ...s configuration wizards bring simplicity to an often complex technology This latest entry into the radar level measurement field is designed to provide unparalleled performance and ease of use The 26...

Page 2: ...ght multiplied by the transit time divided by two Distance C Transit Time 2 Level is then calculated by factoring in tank height and other configuration information Figure 3 The reference point for di...

Page 3: ...Turbulence Medium or Heavy Dielectric 1 7 3 3 10 10 100 1 7 3 3 10 10 100 Antenna Type 11 2 Horn 30 9 40 12 60 18 10 3 16 5 26 8 2 Horn 33 10 49 15 66 20 10 3 20 6 33 10 3 Horn 50 15 66 20 98 30 13 4...

Page 4: ...maximum liquid surface with minimum striking of other objects in the vessel including the tank wall Use these drawings to determine the optimum installation location O B S T R U C T I O N S Almost any...

Page 5: ...perature exposure to the transmitter in high temperature applications a heat extension 032 6922 001 is required between the antenna and transmitter Refer to Operating Temperature Range chart on page 6...

Page 6: ...PTFE POLYPROPYLENE QUARTZ Ambient Temperature F C 40 40 20 29 0 18 20 7 40 4 60 16 80 27 100 38 120 49 140 60 160 71 180 82 700 371 750 400 600 315 500 260 400 204 300 149 200 93 100 38 0 18 100 73 P...

Page 7: ...cannot be handled by the R86 transmitter Unusual flow applications can readily be accomplished through the use of either the 20 point Custom Table or the Generic Discharge Flow Equation which allows a...

Page 8: ...C General purpose ethylene Ketones MEK acetone skydrol fluids amines anhy drous ammonia low molecular weight esters and ethers hot hydrofluoric or chlorosulfuric acids sour HCs Kalrez 4079 2 400 F 23...

Page 9: ...1 2013 ANSI ISA 60079 15 2012 ANSI ISA 60079 26 2011 NEMA 250 2003 ANSI IEC 60529 2004 C22 2 No 0 4 2009 C22 2 No 0 5 2008 C22 2 No 30 2007 C22 2 No 94 2001 C22 2 No 213 2012 C22 2 No 1010 1 2009 CAN...

Page 10: ...HART DD English French German Spanish Russian Chinese Portuguese FOUNDATION fieldbus Host System English Voltage Measured at instrument terminals HART General Purpose Weather proof Intrinsically Safe...

Page 11: ...45 over entire temperature range 40 to 175 F 40 to 80 C Maximum Rate of Change 180 inches 450 cm minute FOUNDATION fieldbus ITK Version 6 2 0 H1 Device Class Link Master LAS selectable ON OFF H1 Profi...

Page 12: ...I F I C A T I O N S I N C H E S M M 12 TRANSMITTER Model Number 3rd Digit Horn Size 11th Digit Extension 1 11 2 2 2 3 3 4 4 Dim H 0 None 3 2 81 4 5 114 8 5 216 11 5 292 Dim L 1 4 6 152 2 8 8 203 8 3...

Page 13: ...ne FOUNDATION fieldbus only 5th digit 2 1 SIL 2 Hardware HART only 5th digit 1 A None FOUNDATION fieldbus only 5th digit 2 ETSI B SIL 2 Hardware HART only 5th digit 1 ETSI 7 ACCESSORIES MOUNTING 0 No...

Page 14: ...150 ASME raised face flange EA DN 80 PN 16 EN 1092 1 Type A 54 3 300 ASME raised face flange EB DN 80 PN 25 40 EN 1092 1 Type A 55 3 600 ASME raised face flange ED DN 80 PN 63 EN 1092 1 Type B2 63 4...

Page 15: ...NS 0 Viton GFLT 2 Kalrez 4079 8 Simriz SZ485 formerly Aegis PF128 NACE A Kalrez 6375 N None Quartz seal mandatory for flame proof ATEX IEC approval 0 None 1 For nozzle height 4 100 mm available only w...

Page 16: ...o be cov ered under the warranty then MAGNETROL will repair or replace the control at no cost to the purchaser or owner other than transportation MAGNETROL shall not be liable for misap plication labo...

Reviews: