Service Policy

Owners of MAGNETROL controls may request the return
of a control or any part of a control for complete rebuilding
or  replacement. They  will  be  rebuilt  or  replaced  promptly.
Controls returned under our service policy must be returned
by  Prepaid  transportation.  MAGNETROL  will  repair  or
replace  the  control  at  no  cost  to  the  purchaser  (or  owner)
other than transportation if:

1.  Returned within the warranty period; and
2.  The factory inspection finds the cause of the claim to be

covered under the warranty.

If the trouble is the result of conditions beyond our control;
or,  is  NOT  covered  by  the  warranty,  there  will  be  charges
for  labor  and  the  parts  required  to  rebuild  or  replace  the
equipment.

In some cases it may be expedient to ship replacement parts;
or, in extreme cases a complete new control, to replace the
original  equipment  before  it  is  returned.  If  this  is  desired,
notify the factory of both the model and serial numbers of
the control to be replaced. In such cases, credit for the mate-
rials returned will be determined on the basis of the appli-
cability of our warranty.

No claims for misapplication, labor, direct or consequential
damage will be allowed.

Return Material Procedure

So  that  we  may  efficiently  process  any  materials  that  are
returned,  it  is  essential  that  a  “Return  Material
Authorization” (RMA) number be obtained from the factory,
prior  to  the  material's  return.  This  is  available  through  a
MAGNETROL  local  representative  or  by  contacting  the
factory. Please supply the following information:

1.  Company Name
2.  Description of Material
3.  Serial Number
4.  Reason for Return
5.  Application

Any  unit  that  was  used  in  a  process  must  be  properly
cleaned  in  accordance  with  OSHA  standards,  before  it  is
returned to the factory.

A  Material  Safety  Data  Sheet  (MSDS)  must  accompany
material that was used in any media.

All  shipments  returned  to  the  factory  must  be  by  prepaid
transportation.

All replacements will be shipped F.O.B. factory.

ASSURED qUALITy & SERVICE CoST LESS

BULLETIN:  44-608.12
EFFECTIVE:  February 2019
SUPERSEDES:  August 2015

705 Enterprise Street • Aurora, Illinois 60504-8149 • 630.969.4000
info@magnetrol.com • magnetrol.com

Copyright © 2019 Magnetrol International, Incorporated

Summary of Contents for TK1

Page 1: ...Side Mounted Liquid Level Float Switch Model TK1 Installation and Operating Manual...

Page 2: ...ve For use in Installation Category II Pollution Degree 2 If equipment is used in a manner not specified by the man ufacturer protection provided by the equipment may be impaired Notice of Trademark C...

Page 3: ...al Number 1 2 Before You Begin Caution During the installation of Model TK1 the float and pivot area must be kept free of metallic particles that might be attracted to the magnet Caution This instrume...

Page 4: ...forces on the float or displacer sensing element Good practice for reducing the likelihood of damage to the control is to equal ize pressure across the device very slowly 1 4 Wiring NOTE A switch or c...

Page 5: ...ged or misplaced obtain a replacement immediately 2 1 2 Inspect Connections Monthly TK1 level switches may sometimes be exposed to excessive heat or moisture Under such conditions insulation on electr...

Page 6: ...e switch is a non magnetic pressure barrier As the liquid level changes the float along with the float magnet moves The magnetic field of the float magnet causes a change of state of the switch making...

Page 7: ...hich may cause binding If binding is present in the float assembly and cannot be cleared by normal cleaning procedures the entire control must be replaced 5 If the complete Model TK1 level switch oper...

Page 8: ...E F G Class III Type 4X IP66 CSA TK1 X0XX BXK Explosion Proof Class I Div 1 Groups C D TK1 X0XX BXC Class II Div 1 Groups E F G Type 4X CE TK1 X0XX XXX Low Voltage Directives Installation Category II...

Page 9: ...C Maximum Process Pressure 1500 psi 103 bar 3 5 2 Electrical Specifications Signal Output Switch closure Type of Contacts SPST SPDT or DPDT Type of Switches Hermetically sealed reed switch Four wire d...

Page 10: ...ith flanged connection and SPST or SPDT switch with flying leads 4 102 Ref 4 5 114 Ref 1 2 NPT Process Opening 3 4 NPT Conduit Opening 4 00 1 75 3 5 6 3 75 3 4 NPT Conduit Opening 1 2 NPT Process Open...

Page 11: ...maximum process pressure 1500 psi TK Side mounted float level switch 3 6 Model Numbers 44 608 TK1 Liquid Level Switch 11 TEChNOlOgy TyPE FlOAT PrOCESS CONNECTION SIZE FlOAT STEM CONNECTION MATErIAl h...

Page 12: ...mate rials returned will be determined on the basis of the appli cability of our warranty No claims for misapplication labor direct or consequential damage will be allowed Return Material Procedure S...