Automatic Measurement (AVM-510A)
9-13
Measurement Parameters Used with Live Video
Parameters
System Video
Color Setup
Frequency
Response
Non-Linear
Transmitter
SYNC AMPL
X
X
X
X
X
BURST AMPL
X
X
X
X
X
PEAK VIDEO
X
X
PEAK LUMA
X
X
APL
X
X
NOISE
X
X
X
H BLANKING
X
H-REF TIMING
X
BURST REF PHA
X
SC/H PHASE
X
COLOR FRAME
X
BAR AMPL
X
X
X
WHITE BAR AMPL
X
BLANKING LEVEL
X
The other measurements (not in italic) are made on the line shown at the top of the measurement
screen and chosen with the
Line Select
and
Field Select
buttons (see Figure 9-5). The one
exception is noise. This parameter is measured on its own special line.