AVM-510A Option T (For Transmission Monitoring)
11-4
Measure Signal ID
The correct signal must be selected so that the zero carrier and the measured signal will be detected
properly.
1.
Press the
Mesmnt
button.
2.
Select
SELECT SET
and then press the
Entr
button.
3.
Select
TRANSMITTER
and then press the
Entr
button.
4.
Select
SIGNAL ID
and then turn the knob to
AUTO SIGNAL ID
. If the signal is known, it can be
set to FCC COMPOSITE, NTC7 COMPOSITE, CCIR 17/330 or NATIONAL ITS.
NOTE:
Refer to “Setting Automeasurement Limits” in chapter 9 for information on
setting measurement limits.
NOTE:
The transmitter measurement set is never selected when
AUTOMEASURE/
AUTO
MEAS SET
is active. It must be manually selected.
Differential Gain and Phase
A 1H line sweep display of differential gain or phase is available for the option T (see Figures
11-3 and 11-4). You select the differential gain function by accessing factory default memory
7. You can also select it by pressing the
VECTOR
button a third time when Input A or B is in
the Composite format.
To set up the differential gain display:
1.
Set the
BURST VECTOR
to 180
°
while in Vector mode.
2.
Press the
VECTOR
button twice.
3.
Vertically position the baseline to zero IRE (% in PAL).
4.
Set the
VARIABLE GAIN
at the top position to 100 IRE (%).
NOTE:
The differential gain reading is the difference in % between the centers of the
peak and the valley of the waveform.
You select the differential phase function by pressing the
VECTOR
button a fourth time. You
can also select it by accessing factory default memory 8.
NOTE:
All settings remain calibrated from the differential gain display.
Summary of Contents for MM-410
Page 16: ...About This Manual 1 4 Notes...
Page 34: ...Installation 4 6 Notes...
Page 48: ...Front Panel Operation 5 14 Notes...
Page 102: ...Viewing Waveforms Vectors and Pictures 7 30 Notes...
Page 126: ...Automatic Measurement AVM 510A 9 20 Notes...
Page 148: ...AVM 510A C For Component Measurements 12 4 Notes...
Page 158: ...Connector Pinouts B 4 Notes...
Page 162: ...Calibration D 2 Notes...