Installation
4-5
8.
Press the
Enter
button to store that memory.
9.
Press the
Clr
Mnu
button to exit.
10.
If you intend to view signals of several different formats, save them in other available memory
locations using steps 1 through 8.
NOTE:
Settings for other formats or standards are also stored. For example, (1) the +V
SWITCH ON/OFF setting for PAL even when memory is stored for NTSC and (2) limit
settings for both standards are stored.
When a configuration is saved in a memory location, all MM-410/AVM-510A functions are
stored in that memory. This includes items that are not displayed. For example, a waveform and
measurement setup when a picture is displayed. For best results, recall a memory location,
make a modification, and then store the new settings in another memory location.
To recall any stored memory at any time, press the
Blue
(2nd) button and then one of the Memory
Recall buttons (for memories 1 through 10).
NOTE:
You can also recall the first four memory locations through the ground closures of
the DC CONTROL/ALARM connector. (see Figures 2-2 and 3-2).
Refer to Chapter 6, “Operating the MM-410/AVM-510A,” for more information about
using the Config menu to save memory locations.
Summary of Contents for MM-410
Page 16: ...About This Manual 1 4 Notes...
Page 34: ...Installation 4 6 Notes...
Page 48: ...Front Panel Operation 5 14 Notes...
Page 102: ...Viewing Waveforms Vectors and Pictures 7 30 Notes...
Page 126: ...Automatic Measurement AVM 510A 9 20 Notes...
Page 148: ...AVM 510A C For Component Measurements 12 4 Notes...
Page 158: ...Connector Pinouts B 4 Notes...
Page 162: ...Calibration D 2 Notes...