Viewing Waveforms, Vectors, and Pictures
7-6
Switching PAL Graticule to Percent
The PAL waveform graticule is scaled, in volts, by default (Figure 7-5). For some measurements you
might want to change this option to percent (Figure 7-6). To switch the PAL graticule from volts to
percent:
1.
Press the
Config
button.
2.
Select DISPLAY and then press the
Enter
button.
3.
Select GRATICULE OPTIONS and then press the
Enter
button.
4.
Select PAL GRATICULE.
5.
Press the
Enter
button or turn the knob to highlight either VOLTS or PERCENT.
6.
Press the
Clr Mnu
button to exit.
Figure 7-5. PAL Volts Graticule
Figure 7-6. PAL Percent Graticule