Appendix A – ME-ARC Compatibility Matrix
Page 129
Button
Features/Settings
Model/
Level
Required
Default
Main
Menu
Menu
Heading/Item
Selections/
Adjustments Range
SETUP
04
AGS
Setup
04D Gen Run SOC
OFF, Start Gen SOC = 20-99%
≥
Level 1
[6]
OFF
Stop Gen SOC = 21-100%
90%
04E Gen Run Temp
Start = OFF, Ext Input, 65-95F
(18-35C)
≥
Level 1
OFF
Run Time = 0.5-25.5 Hrs
2.0 Hrs
04F Max Gen Run
Time
OFF, 0.1-25.5 Hrs
≥
Level 1
12.0 Hrs
04G Quiet Time
OFF, ON–Start = 12:00A - 11:45P
≥
Level 1
OFF
Stop Quiet Time = 12:00A - 11:45P
Quiet Time Topoff = OFF, 30-120 Min
OFF
04H Gen Exercise
Days = OFF, 1-255 days
≥
Level 1
OFF
Run Hour/Min/AM-PM = 12:00A -
11:45P
Run Time = 0.1-25.5 Hrs
1.0 Hrs
04I Gen Warm-up
Time
0-127 sec, 1-127 min
≥
Level 1
60 Sec
04J Gen Cooldown
Time
0-127 sec, 1-127 min
≥
Level 1
60 Sec
04K Gen 100% SOC
Start Days
OFF, 1-255 Days
≥
Level 4
[5]
OFF
SOC Hour/Minute/AM-PM =
12:00A - 11:45P
05
BMK
Setup
05A Charge Eff
Auto, 50-99%
≥
Level 1
[6]
Auto
05B AmpHour Size
200-2500 AH
≥
Level 1
[6]
400 AH
06
PT
Setup
06A Battery Type
Gel, Flooded, AGM1, AGM2
≥
Level 1
Flooded
CC/
CV
Max Charge = OFF, 20-990A
≥
Level 1
200 ADC
CV Charge = 12.0-16.6* VDC
13.8*
CV Chg Done = Time, Amps,
Hold CV Chg VDC
Time
Time = 0.1-25.5
2.0 Hrs
Max CC/CV Time = OFF,
0.1-25.5 Hrs
12.0 Hrs
Recharge = 9.0-16.0* Volts
12.0*
Absorb (12.0-16.6)*
≥
Level 1
14.4*
Float (12.0-16.6)*
13.2*
EQ (12.0-16.6)*
15.6*
EQ Done (0.1-25.5)
4.0 Hrs
Custom