General Repair Information
14
312004B
General Repair Information
Trigger Lock
Always engage the trigger lock when you stop spraying
to prevent the gun from being triggered accidentally by
hand or if dropped or bumped.
Pressure Relief Procedure
Follow this
Pressure Relief Procedure
whenever you
stop spraying and before cleaning, checking, servicing,
or transporting equipment.
1.
Turn power switch OFF and unplug
power cord.
2.
Turn Prime/Spray valve to
PRIME to relieve pressure.
3.
Hold gun firmly to side
of pail. Trigger the gun
to relieve pressure.
4.
Engage trigger lock.
If you suspect the spray tip or hose is clogged or that
pressure has not been fully relieved after following the
steps above, VERY SLOWLY loosen tip guard retaining
nut or hose end coupling to relieve pressure gradually,
then loosen completely. Clear hose or tip obstruction.
Read Unclogging Spray Tip instructions in the Sprayer
or Gun Operation manual.
ti8923a
SG10 Gun
SG10 Gun
ti8922a
Trigger Locked
Trigger Unlocked
ti8908a
ti8909a
SG20 Gun
SG20 Gun
Leave Prime/Spray valve in the PRIME position
until you are ready to spray again.
ti2018a
ti9346a
ti9207a
ti8908a
ti8923a
Summary of Contents for 261800
Page 35: ...Notes 312004B 35 Notes ...
Page 39: ...Notes 312004B 39 Notes ...
Page 45: ...Notes 312004B 45 Notes ...