CONTENTS
STARTUP
•
Connect power cord, Soldering iron, Hot Air Pencil and insert them into their spring
holders
•
Switch on the 3005 Station.
•
The °C (or °F) will appear on the LED display and the Microprocessor will do a 30
second self diagnosis test in which time any fault will be displayed as Err 1 to 4 (1=S/iron
cold, 2=S/iron overheat, 3= H/air cold, 4= H/air overheat)
•
The 3005 SMD Rework Station will automatically start with the factory settings
(S/iron 350°, H/air 400°, Air flow at 60% and energy saving active).
SETTINGS
•
In order to set the desired temperature for the soldering iron press the top button
(channel 1 ) the dots will start flashing
•
During this period the control knob can be turned to set the new temperature
•
Press the middle button (channel 2) to change the hot air temperature
•
Press the lower button (channel 3) to change the air flow
•
The above settings will only take effect after the dots stop flashing (+- 4 seconds)
and the display returns to actual value
•
The corresponding LED will indicate which channel is being displayed
•
The air flow can be intermittently activated by pressing the button on the handpiece
or continuously by switching the air pump switch on the station
•
When the airflow is off (intermittent mode) the Microprocessor automatically
reduces the temperature to save energy and conserve the heating element. The temperature
will be restored when the air flow resumes.