33
The
Magnum 6500/7500
can be installed with and operated by a wall-mounted thermostat. However,
a wall thermostat is not provided with the furnace. A wall thermostat can be purchased from your
reseller or at most home improvement centers or hardware stores. We recommend the Honeywell
model T87F or equivalent low voltage thermostat
Most thermostats will have instructions with them as to where to place them in your room. Please
follow the thermostat manufacturer’s instructions carefully. Use thermostat wire (18/2).
There are two (2) male spade terminals on the back of the control panel near the center. Connect the
two wires from the wall thermostat, one to each of these spade terminals.
Needed:
2 female ¼”
insulated terminals.
Make sure that the wires are routed to protect them from hot surfaces. Do not cross wires with
circuitry on board.
The circuit board is located on the left side of the unit. Remove the ¼” hex head screw and pull
circuit board towards you. Lift the circuit board out of the housing. Do not crimp or stretch the wires
leading from circuit board pigtail.
(Unplug the power cord before working on unit)
Reinstall in reverse procedure.
Operating the furnace with a wall thermostat takes a little experience to get
used to. Heat levels from 2-3 work very well with the wall thermostat but the
heat level 4 or high may require manual air adjustments. Consult with your
dealer to get recommended settings and advice.
It is a good idea to use the thermostat option to achieve uniform control over
your heating needs. By setting the unit on a number 3 setting (this is the
normal setting but can be any setting from 2-high) for high fire and letting
the wall thermostat control it, the fire will drop down into a pilot fire after the
home reaches the desired temperature.
If you are gone and the home requires heat, the unit will automatically
resume the high setting when the thermostat calls for heat
THERMOSTAT INSTALLATION
Two (2) ¼” male spade
connectors, one for each
wire from wall thermostat