5
The Magnum 6500/7500 will burn high ash content fuels but will require additional
maintenance/cleaning.
A working smoke detector must be installed in the same room as this product.
Flammable or explosive liquids such as gasoline, naphtha or engine oil must NEVER be used in or
around this stove. These liquids must be stored well away from this furnace as the open flame in the
burner chamber could ignite the fumes of such liquids.
Do not burn garbage in this unit
.
According to HUD requirements, when installed in a mobile home, this stove must be grounded
directly to the steel chassis of the mobile home and bolted to the floor.
The moving parts of this stove are propelled by high torque electric motors. The auger and Fuel
Stirrer can cause severe injury to body parts that may get near them. Keep all body parts away from
the auger and Fuel Stirrer while the furnace is plugged into an electrical outlet. These moving parts
may begin moving at any time while the furnace is plugged in.
This unit may be installed on a non-combustible surface. Make sure that the unit is level. This unit
must have floor protection of at least 6 inches (150mm) in front and 6 inches (150 mm) on either side
of the fuel loading and ash-removal doors.
Do not attempt internal service to the unit when it is burning and or plugged into power.
It is important to plan your installation so that service work can be performed on the appliance. Leave
ample space around the furnace to open cabinet doors. Minimum clearances to combustibles must be
maintained.
Your Magnum reseller is required to go over in detail with the owner/operator as to the correct
operation of the furnace and its components.
Never block or obstruct any air intake ports including the vents on the furnace panels. Overheating
can occur without proper air movement.
Make sure your circuit is not overloaded as to cause the furnace to lose power.
Furnace must be installed with adequate return and supply duct systems. Failure to have adequate
return air to the furnace will void your warranty.
A minimum rise of 5’ is required on all side vent applications
.
Proper cleaning and maintenance is necessary. You will need to follow the directions for cleaning that
are in this manual. A furnace that is properly maintained and cleaned will give you years of trouble
free performance.
The warm-air supply-duct system must be constructed out of materials that will withstand a minimum
temperature rating of 250 degrees Fahrenheit. Plenums installed to the furnace must be constructed
out of metal.
It is the responsibility of the homeowner to assure proper ducting installation.
The warm-air supply outlet of the supplementary furnace cannot be connected to the cold-air return
inlet of the central furnace (series) because a possibility exists of components of the central furnace
overheating and causing the central furnace to operate other than intended.