The Magnum Wood Pellet Appliances may be installed as follows:
1)
A freestanding unit (with a pedestal only)
2)
A hearth mounted fireplace insert into a masonry or factory built fireplace (T40I only)
3)
A built-in heater mounted in an alcove with a pedestal
4)
A built-in heater mounted on a non-combustible floor without a pedestal
MOBILE HOME INSTALLATION REQUIREMENTS
IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING
REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:
1)
Stove must be permanently bolted to the floor.
2)
Stove must have permanent outside air source.
3)
Stove must be permanently electrically ground to the steel chassis of the mobile home. (12 ga. or larger wire)
4)
All vertical chimney vent must have wall supports every (5) five feet.
5)
All exhaust systems must have a spark arrestor.
INSTALLATION CONFIGURATIONS
WARNING
DO NOT INSTALL IN SLEEPING ROOM
CAUTION
The structural integrity of the mobile home floor, wall and ceiling must be maintained.
Check with your local building official as other codes may apply.