background image

1

Magnum First - 1930 Baseline Road, Grand Island, NY 14072 - phone 716-293-1588 - www.magnumfirst.com - info@magnumfirst.com

Product Installation Guide

Integrated Rocker 

Switch 

M

9

-ILS2

1] Description

2] Features

4] Installation (continued)

The Mx-ILS2 Rocker Switch is designed to use wireless communication (902 MHz) and provide remote control 
of your lighting. The relay will turn the load ON when the top button is pressed and OFF when the bottom button 
is pressed. The Indicator LED will blink Red when a message is received from a learned wireless device such 
as an occupancy sensor or remote switch. NOTE: The no-neutral version of the WSS20 has a minimum load 
requirement of 25 watts.

Devices can be learned directly into the Mx-ILS2 via the Programming Mode Selection Menu or via airConfig 
Tool. The Mx-ILS2 rocker switch has a 100-150 ft. reception range depending upon the environment and 
transmission device. Range will be reduced by signals having to transmit through walls. Transmit range for 
Mx-ILS2, when utilized as a repeater or for initial setup/ commissioning is approximately 50ft.

INSTALLING YOUR ILS2 SWITCH

Step 1: WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test 
that power is off before wiring!

Step 2: Identifying your wiring application (most common): 
NOTE: If the wiring in your wall box does not resemble this 
configuration, consult an electrician.

Step 3: Single Pole Wiring Application
• ILS2 Receiver Control Switch is only intended as a Single Pole device.
Multiple Location Wiring Application:
• Wireless remote switch can be used for additional switches (3-way and 4-way), no wires necessary.

Wiring Switch:
Connect wires per WIRING DIAGRAM below as follows:
• Connect (Hot) wire from wall box to black wire on switch.
• Connect (Load) wire in wall box to blue wire on switch.
• Connect (Neutral) wire in wall box to white wire on switch. (NOTE: For No Neutral model, white wire will not be 
available (Figure 2).

Step 4: Dip Switch Settings:
NOTE: Dip switch settings, the switch frame and paddle will need to be
removed. Refer back to the “Changing the color of your ILS2 switch” section for removal instructions of the 
switch frame. This can only be done with the wall plate removed.

• Able to switch single load ON/OFF remotely
• Scene Capable
• Green Locator LED when device is OFF
• Can be remotely configured and commissioned using the airConfig Tool
• Includes repeater function to increase wireless reception to other devices 
• Ease of installation - no new wiring
• Title 24 Vacancy Mode (Manual ON/Auto OFF) supported when paired with occupancy sensor
Mx-ILS2 has built in air-gap switch to disable current flowing to the load for replacing bulbs

3] Equipment Needed For Installation

4] Installation

• Slotted/Phillips Screwdriver 

• Pencil

• Electrical Tape 

• 

Cutters

• 

Pliers

• 

Ruler

Changing the color of your ILS2:

Your ILS2 switch includes three color options. The ILS2 switch ships with the white frame attached. To change 