Auto-ON / Auto-OFF mode:

 Auto mode can be enabled using the dip switches, product comes from the factory 

in Manual-ON/Auto-OFF. 

Walk-through: 

Can be used only in Auto-ON mode. It is recommended to only use this setting when wireless 

occupancy sensors with batteries have been installed.

Timeout:

 2 (test), 10, 20, 30min; (Longer time delay is recommended for continuous self-powering of the occu-

pancy sensor and to ensure packets are sent to the WSS20 receiver switch.

Step 6: Switch Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE: 

The locator LED will illuminate GREEN when the load is in the OFF position to facilitate access in the dark.

Push Pad (Default settings)

- Turn ON from OFF position: Push the top of the switch.
- Turn OFF from ON position: Push the bottom of the switch.
- Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners.

If there is a power outage, when the power is restored, the lights will return to the last known state so long as 
the device was in that state for 30 seconds or more.

INSTALLING AIRCONFIG SOFTWARE (OPTIONAL)

Please refer to the Magnum AirConfig tool available at 

http://download.magnum-innovations.net

.

Programming Instructions:

All devices are learned in a “reduced sensitivity” mode to avoid interference from other devices which may be 
active in areas close by. This reduction of sensitivity reduces the range so devices learned to the ILS2 Rocker 
Switch should be within 10 ft when learning.

Factory settings:

ILS2: Manual ON/Auto OFF, Walk Through mode OFF (disabled), Occupancy Time-Out delay = 20min, Key 
Card/Momentary Time-Out delay = 0s, Repeater = disabled.

Step 7: Wall Plate Mounting:
Place plastic/nylon wallplate over device and secure in place with screws provided.
Note: Usage of a metal wall plate may result in reduction, or loss of receiving range for ILS2 wall switch.

Step 8: Restore Power:
Restore power at circuit breaker or fuse.

Installation is complete.

Tighten mounting screws to secure the device to the wall box.

Step 5: Testing your ILS2 prior to mounting in wall box:

• Position all wires to provide room in outlet wall box for device.
• Ensure that the locator LED is facing up on device.
• Partially screw in mounting screws in wall box mounting holes.

NOTE: Dress wires with a bend as shown in diagram in order to relieve 
stress when mounting ILS2

• Restore power at circuit breaker or fuse.
• Press pad at the TOP until locator LED is OFF. Lights should turn ON.

If lights do not turn ON, refer to the TROUBLESHOOTING section.