background image

Use and installation manual for a MAGNUM sauna stove  

16.06.2015  3 

Starsauna Oy 

 

Technical support: 

 

Pistotie 4 

 

info@magnumkiuas.fi 

15860 Hollola, Finland 

 

 

Safety instructions:

 

 

 

Read these instructions carefully before 
installing and using the sauna stove. 
 

 

These instructions are intended for the use of 
the owner of the sauna and the electrician who 
installs the sauna stove. The owner of the sauna 
receives the instructions for setting up and 
using the sauna stove after the stove has been 
installed. 
 

 

Malfunctions caused by errors in installation or 
use are not covered by the warranty. THIS 
INCLUDES ERRORS IN THE PILING OF 
ROCKS! 

 

 

Do not open the cover of the sauna stove’s 
junction box while the stove is on. 

 

 

Before beginning the installation process, verify 
that the device is de-energized (has been 
disconnected from the power supply). 

 

 

Furthermore, ensure that the device has been 
grounded properly. 

 

 

Do not touch the components or microcircuits 
inside the device, as the electrostatic discharge 
could damage the device. 

Summary of Contents for Original Series

Page 1: ...Original Sauna Stove 6 6 kW 9 0 kW 10 5 kW MAGNUM Cenik and Lite Sauna Stove 6 6 kW 9 0 kW 10 5 kW Magnum Ruutu L and C 6 6kW 9 0kW 10 5kW Use and Installation With Finlandia and Magnum RC Control Ce...

Page 2: ...ature 7 2 3 Heating time 7 2 4 Timer 8 2 5 Turning the sauna on 8 2 6 Directions for using the sauna 9 3 Installation of the sauna stove 10 3 1 Installation 11 3 2 Installing the thermostat sensor 13...

Page 3: ...instructions for setting up and using the sauna stove after the stove has been installed Malfunctions caused by errors in installation or use are not covered by the warranty THIS INCLUDES ERRORS IN T...

Page 4: ...immediately 2 Menu button By pressing this you can move through the menus of the device as follows Default mode Target temperature Heating time Timer Default mode 3 button This button is used to decr...

Page 5: ...sauna immediately 2 Menu button By pressing this you can move through the menus of the device as follows Default mode Target temperature Heating time Timer Default mode 3 button This button is used to...

Page 6: ...other using the Menu button When the sauna stove is on the and buttons may be used to move to the mode where you can adjust the settings in the order shown in the image above 1 4 Menu structure Magnum...

Page 7: ...na temperature is on the display pressing the or button causes the controller to move directly to setting the target temperature Leaving this menu is done as in section 1 Section II 3 Heating time You...

Page 8: ...heating the sauna until the target temperature has been reached The stove s indicator light in the controller will be turned on The decimal mark lights up on the lower right side of the screen as a si...

Page 9: ...a and the ventilation Use water that is suitable for domestic use when throwing water on the stove for heating the sauna Do not throw water on the stove if there are people next to it as the water spl...

Page 10: ...llation work may only be performed by an electrician qualified for the job in accordance with applicable regulations The sauna stove is connected to the power grid semi permanently with H07RN F or sim...

Page 11: ...In the Lite Cenik model turn the sauna stove on its side against a clean platform Make sure the sauna stove is not scratched 4 Open the hatch at the base of the sauna stove and connect the feeder line...

Page 12: ...e the stones have been installed 13 Install the stainless steel frame of the upper part of the sauna stove Chapter 4 3 image 3 14 Pile the stones in the upper part of the sauna stove in a way that ens...

Page 13: ...or and press it carefully all the way down When installing the thermostat sensor on the wall the distance from the roof to the upper edge of the sensor should be 100 mm The sensor must be located 500...

Page 14: ...ctor card to the sauna stove is the same for the Finlandia and Magnum RC models Connecting the Finlandia controller card Connecting from the left The Control panel can be installed inside the sauna In...

Page 15: ...ve as set in Chapter 3 3 NOTE The electric grid connection process may only be performed by a licensed electrician The bottom of the box is not delivered with the sauna stove One suitable box is the A...

Page 16: ...sauna stove is 500 1000 mm PAY ATTENTION TO THE INCOMING AIR VALVE If incoming air cannot be directed away from the thermostat the valve may not be installed less than 1000 mm from the incoming air v...

Page 17: ...AGNUM sauna stove 16 06 2015 17 Starsauna Oy Technical support Pistotie 4 info magnumkiuas fi 15860 Hollola Finland 4 2 Ventilation in the sauna room Power ventilation for the sauna and the electric s...

Page 18: ...level of the sauna stove where you can check the straightness Check the straightness in both directions adjust with the adjustment feet If no stones have been piled into the sauna stove yet the adjus...

Page 19: ...ling stones in the sauna stove Ensure that there are enough stones on top It is recommended to choose big stones for the top of the sauna stove so that they cannot fall through the vertical profiles 7...

Page 20: ...in Ruutu sauna stoves anywhere between the squares 2 Bend the brackets if necessary PLEASE NOTE if you are bending the brackets by hand use protective gloves 3 When the bracket seems to be positioned...

Page 21: ...Number of stones approx 80 kg approx 80 kg approx 100 kg Lite 6 6 Lite 9 0 Lite 10 5 kW Power 6 6 KW 9 KW 10 5 KW Diameter of the lower part 320 mm 320 mm 320 mm Diameter of the upper part 320 360 mm...

Page 22: ...60 mm Fuse 3x10A 3x16A Connection Cable 5x1 5 mm2 5x2 5 mm2 Stone Amount n 120kg n 120kg 5 2 Safety distances Minimum safety distances MAGNUM ORIGINAL MODELS Sauna stove 700 mm to the lower bench Over...

Page 23: ...6 6 kW and 9 kW 360 mm 100 mm Tulip 6 6 kW and 9 kW 360 mm 100 mm Pillar 6 6 kW 9 kW and 10 5 kW 320 mm 125 mm Reed 10 5 kW 360 mm 100 mm Vase 10 5 kW 370 mm 100 mm Tulip 10 5 kW 370 mm 100 mm CENIK u...

Page 24: ...nual for a MAGNUM sauna stove 16 06 2015 24 Starsauna Oy Technical support Pistotie 4 info magnumkiuas fi 15860 Hollola Finland 5 3 Images showing the safety distances The distances are always measure...

Page 25: ...on during the warranty period The manufacturer may charge for possible spare parts if a warranty term has been breached When troubleshooting for issues outside the scope of the manual the buyer should...

Page 26: ...Use and installation manual for a MAGNUM sauna stove 16 06 2015 26 Starsauna Oy Technical support Pistotie 4 info magnumkiuas fi 15860 Hollola Finland 7 Connection diagram...

Page 27: ...such as when the sensor s short circuit has been removed or an overheated device has cooled down sufficiently After this you may attempt to turn the device on again Error code symptom Legend ER1 There...