Setup/Installation
Model TE100
Electronic Small Bagging Scale
3-2 Revision
001
3.2 Mechanical Setup
Once the TE100 has been moved into the position where it will operate, follow the steps below to setup
the mechanical components for operation.
1. Lift the scale cabinet assembly by its bottom edge and slide the scale cabinet onto the mounting
flange. This may require two people.
Figure 3-2.
Hanging the Cabinet Assembly on the Hopper Flange
2. With the mounting clamps over the flange, center the cabinet under the bin or transition.
3. Tighten the mounting bolts.
4. Use a torpedo level on the top ledge of the cabinet assembly. The cabinet assembly must be
level. Adjust the mounting bolts as needed to get the cabinet assembly level.
5. Remove the shipping bracket.
Figure 3-3.
Shipping Bracket Location
6. Connect the main electrical and pneumatic connections.
7. Set the air pressure regulator. Refer to 3.4 Making Pneumatic Connections.
8. Dry cycle the TE100. Refer to 3.5 Dry Cycle.
9. Calibrate the TE100. Refer to 3.6 Calibration.
3.3 Making Electrical Connections
Before connecting the TE100 to the electrical supply, it is vital that the unit be properly grounded. The
recommended method is to plug the power cord into an earth grounded receptacle.
The TE100 requires 115 VAC at 50 or 60 Hz to operate. The TE100 should be placed within 6 feet of
the electrical outlets that it will be connected to.
3.3.1 Electrical Connections
The following schematic illustrates how the different electrical components fit into the overall electrical
layout of the machine. If any electrical components have to be removed or replaced, use these
schematics to correctly install the valves.
Scale Cabinet Assembly
Mounting Brackets
Mounting Bolts
(2 per side)
Mounting Bolts
(2 per side)
Scale Cabinet
Assembly Top
Ledge
Shipping bracket
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...