Setup/Installation
Revision 001
3-9
Model TE100
Electronic Small Bagging Scale
Control Device
Function
Over/under reject
adjustment
potentiometers
Located on the left side of the controller circuit board. The two potentiometers are used to adjust the
under weight and over weight limit for each package. Each potentiometer has an adjustment range from
0.0 to 0.8 lbs. This feature is especially useful when product density changes rapidly. While the TE100
is compensating for the change of density, the operator will know which bags, if any, are outside of the
acceptable weight range.
Display trim
potentiometer
Located in the upper center of the controller circuit board. This potentiometer is used to adjust full-
scale range of the weight display. While holding the display select switch in the SET WEIGHT
position, turn this potentiometer until the weight display reads 1.24 times the desired target weight.
3.6.1 Weight Display Setup
1. Connect the main electrical and pneumatic connections.
2. Turn the power on. Allow the TE100 controls to warm up for thirty (30) minutes.
3. Check the weight display to see if it is currently set to the desired decimal point location. The
decimal point location can be set to allow the weigh meter to display the package weight to the
nearest tenth (XXX.X), hundredth (XX.XX), or thousandth (X.XXX) of a pound/kilogram. If no
change is needed, proceed to step 4. If the decimal point setting needs to be changed, follow the
sub-steps below:
a. Locate the decimal point placement switches in the upper right corner of the printer
circuit board.
Figure 3-10.
Decimal Point Switches
b. Set the decimal placement:
i. To set the decimal placement for tenths, switch #1 should be ON and all other
switches should be OFF.
ii. To set the decimal placement for hundredths, switch #2 should be ON and all
other switches should be OFF.
iii. To set the decimal placement for thousandths, switch #3 should be ON and all
other switches should be OFF.
Note: Most weighments will be done with the weigh meter set to show the weight to the nearest
tenth (XXX.X) of a pound/kilogram.
Decimal point
placement switches
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...