Setup/Installation
Revision 001
3-11
Model TE100
Electronic Small Bagging Scale
6. Locate the coarse zero adjustment switches. They are located in the lower right corner of the
printed circuit board. The two switches can be set to four unique combinations. Both switches
ON, both switches OFF, switch #1 ON/switch #2 OFF, switch #1 OFF/switch #2 ON. Try all
four combinations. Leave the switches set at the combination that results in the closest reading
to zero.
Figure 3-13.
Coarse Zero Adjustment
7. Loosen the lock collar on the ZERO knob, if not already loosened.
8. Turn ZERO knob clockwise or counter-clockwise until the weight display reads 000.0.
9. Tighten the lock collar on the ZERO knob.
3.6.3 Calibration Of Scale To Full-Scale Weight
1. Check the weight display to make sure that it is displaying zero. The ZERO knob should be
adjusted so that the – (minus) has just disappeared from the display.
2. Attach a wire or small cord to the center of the bag clamp brackets at the bottom of the spout.
The wire or cord needs to be strong enough to safely support the test weight.
3. Zero the scale with the wire or cord attached.
4. Hang a certified test weight from the wire or cord that is attached to the bag clamp brackets.
The test weight should be as close to the desired maximum package weight as possible to help
reduce linear deviation. Linear deviation can occur when a lighter test weight is used to set the
scale gain.
Figure 3-14.
Hanging A Certified Test Weight On The TE100
Coarse zero
adjustment
switches
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...