Setup/Installation
Model TE100
Electronic Small Bagging Scale
3-12 Revision
001
5. Check the weight display. If the display reading matches the weight of the test weight,
calibration is complete.
6. If the display reading is only slightly different that the test weight, try using the WEIGHT TRIM
POT to adjust the display reading to match the test weight.
7. Locate the weight trim potentiometer on the lower right side of the printed circuit board.
Figure 3-15.
Weight Trim Potentiometer
8. Using a small screwdriver, turn the pot either clockwise or counter clockwise until the display
matches the test weight. For example, if using a 50 lb. test weight, and the weight display reads
49.8 lbs., turn the weight trim potentiometer clockwise until the display reads 50.0 lbs. If the
display reads 50.3 lbs., turn the weight trim potentiometer counter-clockwise until the display
reads 50.0 lbs.
9. If the operator is unable to get the weight display to match the weight of the test weight using the
weight trim potentiometer, the operator will need to use the coarse weight gain switches.
10. Turn the weight trim potentiometer all the way clockwise.
11. While counting the number of revolutions, turn the weight trim potentiometer all the way
counter-clockwise.
12. Divide the number of revolutions that the weight trim potentiometer was turned in the previous
step by two to determine where the center of the span is. For example, if the weight trim
potentiometer was turned 10 revolutions, the center of the span would be 5 revolutions
clockwise.
13. Turn the weight trim potentiometer clockwise the number of revolutions determined in the
previous step to center the pot in its span.
14. Locate the coarse weight gain switches. The switches are located on the lower right side of the
printed circuit board, just to the left of the weight trim potentiometer. These switches are a block
of four switches. The four switches can be set to 16 unique combinations, refer to Table 3-2.
Try different combinations until the closest number to the test weight is found.
Figure 3-16.
Coarse Weight Gain Switches
Note: Setting all switches to OFF will result in the lowest weight reading, while setting all
switches to ON will result in the highest weight reading.
Weight trim
potentiometer
Coarse weight
gain switches
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...