Operation
Revision 001
4-3
Model TE100
Electronic Small Bagging Scale
7. Zero (tare) the weight meter.
a. If the weighments are to be based on
Gross Weight
, zero the weigh meter with no bag on
the spout.
b. If the weighments are to be based on
Net Weight
, zero the weigh meter with a bag
attached to the spout.
8. Place an empty bag on the spout.
WARNING
Be sure to keep fingers and loose clothing away from bag clamps.
Failure to do so could result in personal injury.
9. Engage the start switch. The automatic fill cycle will begin.
Note: To stop the machine during a fill cycle, press the
EMERGENCY STOP
pushbutton on the
front of the control panel.
CAUTION
Never pull down on a bag to stop a fill cycle. Failure to follow this
instruction could result in personal injury or damage to the load cell.
10. If the fill cycle stops, but the bag does not drop, the weight of the bag is outside of the
Over/Under reject points. Press the EMERGENCY STOP pushbutton located on the front of the
control panel to drop the bag.
11. Due to the pre-programmed Automatic Weight Correction sequence, the first bags of each run
will be overweight. Each succeeding bag should get closer to the target weight. It will require 5
to 12 bags of material before the Automatic Weight Correction will be able to fully correct to
Target Weight. However, if the first bag is substantially over weight (more than 0.6 pounds), use
the following procedure to reduce the amount of bags required for the Automatic Weight
Correction to reach Target Weight. If the first bag is 0.6 pounds or less overweight, skip ahead
to Step 12.
a. Turn the power off.
Note: The power must be shut off each time this setting is changed. When the power is removed,
the memory for this setting is erased.
b. Open the control panel.
c. Locate the density correction switch on the main circuit board. It is a small box with ten
settings, 0 through 9. The factory preset is 5, which is a 1.0 pound offset. Each setting is
equal to a 0.2 pound increment.
d. Adjust the density correction switch as follows:
i. If first bag weight is 0.7 to 1.0 pounds too heavy, turn density correction switch
up one notch. (For example, from 5 to 6.)
ii. If first bag weight is 1.1 to 1.5 pounds too heavy, turn density correction switch
up two notches. (For example, from 5 to 7.)
iii. If the first bag is more than 1.5 pounds too heavy, leave the density correction
switch at 5 and adjust the Dribble Gate in a little to reduce the rate of material
flow.
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...