Repair
Revision 001
7-5
Model TE100
Electronic Small Bagging Scale
7.3.1.2 Spout Installation
1. Lift the spout and align it so that the bottom of the scale cabinet is slipping into the spout.
2. Once the lip of the spout is above the load cell, slide the spout forward and line the mounting
holes on the spout up with the mounting holes in the load cell.
3. Lower the spout onto the load cell.
CAUTION
A sudden jerk or shock, such as being struck by a tool or hitting the
spout, etc., can cause load cell damage. The load cell is NOT
covered by warranty.
4. Install the two mounting bolts. Do not tighten the bolts yet.
Figure 7-4.
Spout Mounting Bolts
5. Check the alignment of the spout to the scale cabinet. The spout should not be touching the scale
cabinet. The only contact with the scale cabinet or with its components should be where the
spout sits on the load cell.
6. Tighten the spout to load cell bolts. Do not over tighten.
7. Install the start switch.
8. Install the bag clamp actuator switch.
9. Connect the air supply lines that feed the bag clamp cylinders.
10. Connect the main electrical and pneumatic connections.
11. Turn the TE100 on and test for proper operation.
Spout mounting
bolts
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...