Repair
Revision 001
7-7
Model TE100
Electronic Small Bagging Scale
7.3.3 Dribble Gate Cylinder Replacement
If the dribble gate cylinder develops a leak, or is receiving air pressure and fails to function, use the
procedures below to replace it.
7.3.3.1 Dribble Gate Cylinder Removal
1. Turn the TE100 off.
2. Disconnect the main electrical and pneumatic connections.
3. Remove the back cover.
4. Label and disconnect the air supply lines from the dribble gate cylinder.
5. Remove the nut, washer, and bolt that secure the rod end of the cylinder to the dribble gate.
6. Loosen and remove the bolt that secures the cylinder to the cylinder mounting bracket.
7. Remove the dribble gate cylinder.
7.3.3.2 Dribble Gate Cylinder Installation
1. Position the dribble gate cylinder so that the mounting hole on the cylinder end lines up with the
mounting hole in the mounting bracket.
2. Install the bolt that secures the dribble gate cylinder to the mounting bracket.
3. Line the rod end of the pneumatic cylinder with the bolt hole on the mounting tab on the dribble
gate.
4. Insert the bolt through the rod end and mounting tab.
5. Install the washer and nut on the bolt. Tighten the nut on the bolt.
6. Connect the air supply lines to the dribble gate cylinder.
7. Connect the main electrical and pneumatic connections.
8. Turn the TE100 on and test for proper operation.
7.3.4 Dribble Gate Replacement
If the dribble gate becomes damaged or worn, use the steps below to replace it.
7.3.4.1 Dribble Gate Removal
1. Turn the TE100 off.
2. Disconnect the main electrical and pneumatic connections.
3. Remove the dribble gate cylinder. Refer to 7.3.3 Dribble Gate Cylinder Replacement.
4. Remove the dribble gate cylinder mounting bracket bolts and bracket.
5. Slide the dribble gate upward and to the rear of the TE100 until it is clear of the scale cabinet.
7.3.4.2 Dribble Gate Installation
1. Slide the dribble gate into the slots that the gate rides in.
2. Install the dribble gate cylinder mounting bracket.
3. Install the dribble gate cylinder. Refer to 7.3.3 Dribble Gate Cylinder Replacement.
4. Connect the main electrical and pneumatic connections.
5. Turn the TE100 on and test for proper operation.
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...