Setup/Installation
Model TE100
Electronic Small Bagging Scale
3-16 Revision
001
3.6.6 Dribble Gate Setup
After completing the other calibration procedures, the operator should check the operation of the
machine to determine if the dribble gate requires any adjustment. For example, when filling a 50 lb
package in less than 4 seconds, if the package weights are erratic, move the dribble gate in one step.
The result will be a slower fill rate and more stable bag weights.
1. Turn the TE100 off.
2. Disconnect the main electrical and pneumatic connections.
3. Loosen and remove the two bolts that secure the dribble gate cylinder mounting bracket to the
dribble gate rails.
Figure 3-19.
Dribble Gate Cylinder Mounting
4. Move the dribble gate cylinder mounting bracket inward to reduce the feed rate or outward to
increase the feed rate.
5. Install and tighten the two bolts that secure the dribble gate cylinder mounting bracket to the
dribble gate rails.
6. Connect the main electrical and pneumatic connections.
7. Turn the TE100 on and test for proper operation.
Dribble
gate rail
Dribble
gate rail
Dribble gate
cylinder
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...