7.2.3 MAC Valve Flow Control Adjustment
If the operator has determined that the actuation speed of a pneumatic component is either too fast or too
slow, the operator can adjust the actuation speed of that component by adjusting the flow control on the
MAC valve that controls that pneumatic component. Use the steps below to adjust the airflow from the
MAC valve.
1. Locate the MAC valve that controls the affected component.
2. Locate the flow control screw on the top of the MAC valve.
3. Using a screwdriver turn the flow control screw. To increase the actuation speed, turn the
adjustment screw counter-clockwise. To decrease the actuation speed, turn the adjustment screw
clockwise.
Figure 7-3.
Adjusting Airflow From The MAC Valve