Repair
Revision 001
7-9
Model TE100
Electronic Small Bagging Scale
Figure 7-6.
Shut Off Gate Mounting
8. While holding the shut off gate with one hand, remove the shut off gate mounting bolts.
9. Remove the shut off gate.
7.3.6.2 Shut Off Gate Installation
1. Position the shut off gate so that the mounting holes are lined up with the mounting holes in the
scale cabinet.
2. Insert the two slotted screws through the mounting holes. The heads of the screws should be
inside the scale cabinet.
3. Install and tighten the nuts on each of the two slotted screws. Do not over tighten.
4. Use a grinder to grind any portion of the screw shank that extends beyond the outer surface of
the nut. This is done to provide clearance for mounting the spout.
Figure 7-7.
Shut Off Gate Mounting Screw Ground Off Smooth
5. Install the shut off gate cylinder. Refer to the 7.3.5 Shut Off Gate Cylinder Replacement.
6. Install the spout. Refer to the 7.3.1 Spout Replacement.
7. Connect the main electrical and pneumatic connections.
8. Turn the TE100 on and test for proper operation.
Shut off gate mounting
screw and nut (end of screw
is ground flush with nut for
spout clearance)
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...