Repair
Model TE100
Electronic Small Bagging Scale
7-14 Revision
001
7.3.11 Bag Clamp Pivot Block Replacement
If one of the bag clamp pivot blocks becomes damaged or worn, or is receiving air pressure and fails to
function, use the procedures below to replace it.
7.3.11.1 Bag Clamp Pivot Block Removal
1. Turn the TE100 off.
2. Disconnect the main electrical and pneumatic connections.
3. Remove the spout. Refer to the 7.3.1 Spout Replacement.
4. Place the spout assembly on a workbench upside down.
5. Remove the chain link clip from both chain links attached to the pivot block.
6. Loosen the jam nut on the cylinder rod at the pivot block.
7. Make a mark, using a permanent marker, on the cylinder rod.
8. Rotate the rod to back it out of the pivot block threads. Count the number of rotations until the
rod is free of the pivot block.
Figure 7-12.
Bag Clamp Pivot Block
7.3.11.2 Bag Clamp Pivot Block Installation
1. Position the pivot block. Slide the pivot block over the chain link pins.
2. Start threading the rod into the pivot block. Count the number of rotations. Stop when the
number of rotations equals the number of rotations counted in the removal procedure.
3. Tighten the jam nut against the pivot block.
4. Install the chain link clip.
5. Install the spout. Refer to the 7.3.1 Spout Replacement.
6. Connect the main electrical and pneumatic connections.
7. Turn the TE100 on and test for proper operation.
Bag clamp pivot
block (1 of 2
shown)
Summary of Contents for TE100
Page 1: ...Taylor Products Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual ...
Page 6: ...Model TE100 Electronic Small Bagging Scale iv Revision 001 This Page Intentionally Left Blank ...
Page 86: ......
Page 88: ......
Page 90: ......
Page 91: ...Machine Type TE100 Dwg Name ISO 4 dwg Dwg View Scale Cabinet Exploded View ...
Page 92: ......
Page 95: ...Machine Type TE100 Dwg Name ECT146ASY dwg Dwg View Controller Circuit Board ...