36
AUTOMATIC FEATURES
A.
THERMOSTAT OPTION (Optional):
When using a thermostat, set the unit to one of the medium or higher settings. The unit will
burn at the rate selected on demand by the thermostat (medium to high). When the room
temperature drops below the thermostat setting, the thermostat switch will close, allowing the
unit to operate at the medium or higher settings. When the room temperature matches the
thermostat setting, the thermostat switch will open, allowing the stove to operate at the low
setting.
B.
THERMOSTAT EQUIPMENT REQUIRED
(is optional): A low voltage millivolt
thermostat that will automatically switch between settings previously selected.
Type CL2 thermostat wire-20 AWG, 2 conductors.
C.
VACUUM PRESSURE SWITCH/STOVE PRESSURE SENSOR:
A blocked flue, a down draft, open door, open hopper lid, negative or positive pressure in the
home, drafty location of the appliance, not hooking up the outside air, improper venting or
maintenance of the 3” inch exhaust venting from the stove will cause the pressure switch to
shut off the auger. To resume operation, it is necessary to locate the cause and correct it.
Restart the unit following the instructions in this manual.
D.
HIGH TEMP THERMODISK/SNAP DISK:
If the unit overheats, it will shut itself down safely. The unit may not be restarted until it has
cooled and the reset button is depressed. (See Thermodisk location section) If the auger does
not turn after cleaning the back of the unit, you might have tripped this disk. To reset high
temp push in on the center button until it clicks into place.
E.
SELF-IGNITER (Optional):
Automatically ignites the pellets within 3-5 minutes, without the use of fire starter. The igniter
will continue to run for approximately 10 minutes until a fire is established. If the fuel is wet,
poor quality or the hopper has not been primed, it might take 2 or 3 cycles for the unit to
properly light. Using a small amount of fire starter will help with this.
F.
PROOF OF FIRE THERMODISK/SWITCH/SNAP DISK:
If the temperature required by the PROOF OF FIRE thermodisk is not high enough within the
10 (15 minutes on the AC models) minute cycle, the auger will stop feeding fuel.
G.
COOL DOWN SENSOR/SWITCH/LOW LIMIT: (Same as Proof of Fire Thermodisk)
After the power switch has been moved to the “OFF” position, the blowers will continue to run
for approximately 45 minutes. The cool down sensor will allow the stove to cool down and
then automatically shut itself off. If the hopper runs out of fuel and the stove cools off, the
auger will stop feeding. However, the blowers will continue to run until the POF switch has
cooled down to initiate the shut down cycle
Summary of Contents for Winchester WINACI
Page 21: ...21 MAGNUM WIN INSERT INSTALLATION ...
Page 25: ...25 ...
Page 26: ...Fireplace Insert Shroud Installation Diagram 26 ...
Page 27: ...27 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup ...
Page 42: ...42 DC MODEL DDC 3000 WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT ...