10
1.
Turn power
switch OFF.
Shutdown and Cleaning
For short shutdown periods (breaks on the job), leave
suction tube and prime tube in paint, and relieve the
pressure by turning the Spray/Prime valve to PRIME
(see WARNINGS sheet). For extended shutdown
periods, clean sprayer by flushing as instructed in this
section.
4.
Unscrew tip & guard from gun, and place them in waste pail.
PRIME
WASTE
See Pail Flushing in the enclosed Operating Instructions for flushing after
spraying non-water/solvent coatings.
Fluid Injection Hazard
See WARNINGS sheet.
WASTE
Power Flushing After Spraying Water-Base Paint
PRIME
(to relieve pressure)
2.
Place suction tube
and prime tube in
empty waste pail.
3.
Turn Spray/Prime
valve to PRIME to
relieve pressure.
11
Power Flush
attachment
8.
Unscrew inlet screen from
suction tube, and place it in
waste pail.
WASTE
WASTE
Shutdown and Cleaning
WASTE
Power Flushing After Spraying Water-Base Paint
inlet screen
close
6.
Turn on water, and
rinse paint off suction
tube, prime tube, and
inlet screen.
7.
Turn lever to
close Power
Flush
attachment.
5.
Screw Power Flush
attachment onto
garden hose, and
open Power Flush
attachment.
garden hose
open
closed
Power Flush
attachment
9.
Connect garden hose to suction
tube with Power Flush attachment.
Leave prime tube in waste pail.
garden hose