SPECIFICATIONS
www.maxcessintl.com
DLCA NET-ECAT
MI 850A365 1
Page 69 of 72
11.0
Specifications
General
Supply voltage range - 24 VDC ±10%
Proper earth grounding is required.
Note that the negative supply and earth ground
are interconnected on the product.
The power supply must have an SELV output, such
as Puls ML15.241, Mean Well MDR-20 to 24 or
equivalent.
The Mean Well MDR-20 to 24 can be purchased
from Fife as part number 93157-024.
Supply current - 250 mA, maximum
Internal fuse - 6.3 A, fast blow
Display - 6-digit LED, 3 digit tension resolution.
Display decimal point - Selectable position
Maximum gain - 32:1
Tare adjustment - 90% of load cell rating.
Tension update rate - 2 ms
Tension resolution - 14-Bit
Ethernet - 2 ports
10/100 Mbps
Fieldbus support - EtherCAT®
EtherCAT is a registered trademark and
patented technology licensed by Beckhoff
Automation, GmbH, Germany
Temperature range
Operating
Storage
-
-
0° to 60°C (32° to 140°F)
-20° to 80°C (-4° to 176°F)
Enclosure - IP20