Testing Calibration
–
Configuration 2
–
Multi-Step Learn
If the South Pole Signal and North Pole Signal Position are equal to the minimum of the Calibrated Part Present signal
range:
1.
Magnet is electrically de-actuated, by issuing Magswitch Full Off command:
a.
Magswitch Full Off indication LED turns On
b.
Check below table for the expected LED Indication values at this step
Indication LED
Value
S Pole On
Off
N Pole On
Off
Part Present
Off
2.
Unit positioned within Calibrated Part Present signal range and the magnet is electrically actuated between 2% and
99%, by setting Requested Position as any value between 2 and 99(Magnet 2%-99% ON):
a.
Magswitch Partial On indication LED Turns On
b.
Check below table for the expected LED Indication values at this step
Indication LED
Value
S Pole On
Off
N Pole On
Off
Part Present
Off
3.
Unit positioned within Calibrated Part Present signal range and the magnet is electrically actuated on (100%), by setting
Requested Position = 100 (Magnet 100% ON) or issuing Turn Magswitch Full On command:
a.
Magswitch Full On indication LED Turns On
b.
Check below table for the expected LED Indication values at this step
Indication LED
Value
S Pole On
On
N Pole On
On
Part Present
On
4.
Unit positioned with South Pole outside of Calibrated Part Present signal range and the magnet is electrically actuated on
(100%), by setting Requested Position = 100 (Magnet 100% ON) or issuing Turn Magswitch Full On command:
a.
Magswitch Full On indication LED Turns On
b.
Check below table for the expected LED Indication values at this step
LED Indication
Value
S Pole On
Off
N Pole On
On
Part Present
Off