background image

Accessing the Reader

Remove from Counter

In order to access the reader from 

the device stand you may need 

to unscrew it from the counter.  

Unscrew the two screws attaching the 

baseplate of the stand to the counter. 

Remove Base Plate from Stand

Unscrew the two set screws from the 

base plate.

Remove USB-C Cable

Unplug the USB-C cable from the 

back of the device, release the cable 

from pinch fit opening, and remove 

from the integral cable hooks.

Remove 4 Set Screws

Unscrew the 4 screws that attach the 

stand to the reader.

Underside of Device

Form Factor: 

of DynaProx and 

DynaProx BCR are the same smooth 

form factor with 4 threaded screw 

holes, a USB-C receptacle, RS-232 

receptacle, and product label. 

Product Label: 

located on the 

underside of the device. The Serial 

Number, Rev, Date, Part number 

(PN), and Hardware PN (HW) are 

listed. Compare hardware ID to PCI 

website for validation. 

USB-C Connection:

 Connected 

directly to the correct host USB port.

Imprints:

 in the plastic form factor 

of certification logos and patent 

information are listed. 

RS-232 Connection:

 Connected 

directly to the correct host port.

EMV® is a registered trademark in the U.S. and other countries and an unregistered trademark elsewhere. The EMV trademark is owned by EMVCo, LLC. The Contactless Indicator mark, consisting of four graduating arcs, is a trademark owned by and used with permission of EMVCo, LLC.

Registered to ISO 9001:2015 © Copyright 2022 MagTek, Inc. PN D998200542 rev. 20  7/22

MagTek  

®

 Inc., 1710 Apollo Court, Seal Beach CA 90740 | p 562-546-6400 | support 651-415-6800 | f 562-546-6301 | www.magtek.com

D

C

B

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

A

SHEET 1 OF 1

DESIGNED BY

DO NOT  SCALE DRAWING

DRAWN BY

TOLERANCE:

TITLE:

B

SIZE

PROPRIETARY AND CONFIDENTIAL

FINISH:

  4.00 x 2.8265”     

DWG REV : 

CHECKED BY:

DATE

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

MAGTEK.  ANY REPRODUCTION IN PART

OR AS A WHOLE WITHOUT THE WRITTEN

PERMISSION OF MAGTEK IS PROHIBITED.

SCALE: 1:1

MUST BE ROHS COMPLIANT, SEE 

EUROPEAN DIRECTIVE 2002/95/EC

DIM UNITS:

DWG NO.

MATERIAL:

PART  NO.

1/10/2022

R.Robinson

R.Robinson

DynaProx & DynaProx BCR

EMV and NFC Contactless

DynaProx STORAGE NOTICE

TEMPERATURE:

 -30°C to +85°C (-22°F to 185°F)

HUMIDITY: 

 90% RH non-condensing

DynaProx BCR STORAGE NOTICE

TEMPERATURE:

 -40°C to +70°C (-40°F to 158°F)

HUMIDITY: 

 5 - 95% non-condensing

See product label for part number and description.

In-house Zebra label

PN 99600120

LABEL, STORAGE NOTICE, DYNAPROX

AND DYNAPROX BCR

1000008550

D100006015

B0

DynaProx and DynaProx BCR Stand | Device Inspection

Include the following for your device inspection audit:

• 

Be certain to have a list of the devices and include the details listed on the 

product label. 

• 

It may be helpful to take photos of the top, back, and side of each device.

Be certain to check device part numbers, serial numbers and IDs and check 

physical connections. Use the chart below as a checklist to inspect the device 

for signs of tampering. 

Are there signs of tampering:

Signs of tampering

Site Inspection

YES

NO

Form Factor - check overall form factor
Top
Contactless Landing Zone
LEDs
Barcode Reader Camera
Front, Left, and Right Sides
Plastic Shell
Form Factor
Cables
USB-C Cable
Bottom and Back
Form Factor
Cable Connection
Screw Sets

User should report all signs of tampering as per standard protocol.

NOTICE: 

If there is forced entry, the security switches built into the electronics 

will be tampered. If they are tampered the sensitive data such as encryption 

keys and certificates are cleared as part of security measures mandated by 

PCI and the device will not be available to make transactions. If the device has 

detected a tamper, DynaFlex Products cannot be repaired in the field. Follow 

RMA procedures. Devices must be returned to the factory for repair. 

PCI DEVICE VALIDATION

To check for PCI Validation check the Hardware and Firmware ID. Hardware ID 

is printed on the label. The firmware ID is accessible via a host command and is 

displayed. Go to the PCI compliance web page and search for MagTek, and find 

the product name, DynaFlex. Compare the Hardware ID and Firmware ID:

https://www.pcisecuritystandards.org/assessors_and_solutions/pin_transaction_devices

Device Inspection

Access Inspection - Views from Stand Bottom

Full Assembly

Diagram shows assembly pieces.

• 

2-set screws

• 

Base plate

• 

4 mounting screws

• 

Angled stand and cable

• 

DynaProx product

Reviews: