19
SECTION 4. TROUBLESHOOTING GUIDE
REQUIREMENTS
•
Personal Computer.
•
USB Interface Cable, Part Number: 22350300
•
AC adapter, Part Number: 71100001
•
Sample checks, Part Number: 96530005.
SET-UP
1.
Plug USB cable into the ImageSafe Scanner.
2.
Plug the other end of the USB cable into the PC.
3.
Power on the ImageSafe Scanner.
4.
Start trouble-shooting procedure at Step 00.
TROUBLESHOOTING
00
Check LED
Check the status of the LED indicator:
◊
Off, continue to step 01.
◊
Green, continue to step 02.
◊
Blinking red, continue to step 07.
◊
Red, continue to step 12.
01
Check the Power to the ImageSafe Scanner
Possible causes for this problem are:
•
AC adapter connection to outlet - make sure the AC adapter is securely connected to outlet
on the wall or power strip.
•
AC adapter connection to ImageSafe Scanner - make sure the AC adapter is securely
connected to the power jack on the Cable.
•
Power strip - if using a power strip, make sure the strip is connected to outlet on the wall and
the switch on the strip is turned on.
•
AC adapter is defective - replace the AC adapter.
Determine if any of the conditions described above are true:
◊
If yes, rectify and continue to step 00.
◊
If no, continue to step 12.
02
Read a check
Read a check through the ImageSafe Scanner:
◊
If the check is transported all the way around the check path, continue to step 03.
Summary of Contents for IMAGESAFE