Maguire Products, Inc.
Rev. March 5, 2018 – VBD-1000 Touchscreen
20
VBD
- Vacuum Dryer
Electrical Connection
RISK OF INJURY!
Only qualified
technicians should
make electrical
connections.
Connect Main Power
The electrical cable located on the left side of the Dryer on the power
box supplies the power to the Dryer. Within the cable is four wires.
Three of the wires are black and labeled with a number: 1, 2, and 3.
The fourth wire is a green/yellow wire and is the ground wire.
Connect power to a properly fused disconnect.
See page 81 for the High Voltage Wiring Diagram
THREE PHASE:
60 cycle 480 volts
or 50 cycle 400 volts
Confirm Correct 3-Phase Electrical Connection
THREE PHASE Unit - CONFIRM proper 3-Phase power connection
by following these instructions:
Turn power on using
main power switch.
On the outside of the electrical
box below the power switch is
a red 3-Phase indicator light.
If 3-Phase power is correctly
connected, the controller will
power up and the red indicator
light will NOT be lit.